doc: add section to FAQ on improving accuracy with NTP
This commit is contained in:
parent
dd12303276
commit
949ef3e1dc
1 changed files with 37 additions and 0 deletions
|
@ -4628,6 +4628,43 @@ On Linux, if @code{chronyd} is compiled with support for Linux capabilities
|
|||
the `-u' option or @code{user} directive in the @file{chrony.conf} file to drop
|
||||
root privileges after start. The configure option @code{--with-user} can be
|
||||
used to drop the privileges by default.
|
||||
|
||||
@subsection How can I improve the accuracy of the system clock with NTP sources?
|
||||
Select NTP servers that are well synchronised, stable and close to your network.
|
||||
It's better to use more than one server, three or four is usually recommended as
|
||||
the minimum, so @code{chronyd} can detect falsetickers and combine measurements
|
||||
from multiple sources.
|
||||
|
||||
There are also useful options which can be set in the @code{server} directive,
|
||||
they are @code{minpoll}, @code{maxpoll}, @code{polltarget}, @code{maxdelay},
|
||||
@code{maxdelayratio} and @code{maxdelaydevratio}.
|
||||
|
||||
The first three options set the minimum and maximum allowed polling interval,
|
||||
and how should be the actual interval adjusted in the specified range. Their
|
||||
default values are suitable for public NTP servers, which normally don't allow
|
||||
too frequent polling, but if you run your own NTP servers or have permission to
|
||||
poll the servers frequently, setting the options for shorter polling intervals
|
||||
may significantly improve the accuracy of the system clock.
|
||||
|
||||
The optimal polling interval depends on many factors, this includes the ratio
|
||||
between the wander of the clock and the network jitter (sometimes expressed in
|
||||
NTP documents as the Allan intercept), the temperature sensitivity of the
|
||||
crystal oscillator and the maximum rate of change of the temperature. An
|
||||
example of the directive for a server located in the same LAN could be
|
||||
|
||||
@example
|
||||
server ntp.local minpoll 2 maxpoll 4 polltarget 30
|
||||
@end example
|
||||
|
||||
The maxdelay options are useful to ignore measurements with larger delay (e.g.
|
||||
due to congestion in the network) and improve the stability of the
|
||||
synchronisation. The @code{maxdelaydevratio} option could be added to the
|
||||
previous example
|
||||
|
||||
@example
|
||||
server ntp.local minpoll 2 maxpoll 4 polltarget 30 maxdelaydevratio 2
|
||||
@end example
|
||||
|
||||
@c }}}
|
||||
@c {{{ S:Computer is not synchronising
|
||||
@node Computer is not synchronising
|
||||
|
|
Loading…