sourcestats: clamp minsamples and maxsamples in initialization
Don't leave the variables set to values outside their effective range. This has no functional impact, but makes it clear what is the precedence of the two settings.
This commit is contained in:
parent
43ae0131cd
commit
f9af2f9733
1 changed files with 2 additions and 2 deletions
|
@ -211,8 +211,8 @@ SST_CreateInstance(uint32_t refid, IPAddr *addr, int min_samples, int max_sample
|
|||
SST_Stats inst;
|
||||
inst = MallocNew(struct SST_Stats_Record);
|
||||
|
||||
inst->min_samples = min_samples;
|
||||
inst->max_samples = max_samples;
|
||||
inst->max_samples = max_samples > 0 ? CLAMP(1, max_samples, MAX_SAMPLES) : MAX_SAMPLES;
|
||||
inst->min_samples = CLAMP(1, min_samples, inst->max_samples);
|
||||
inst->fixed_min_delay = min_delay;
|
||||
inst->fixed_asymmetry = asymmetry;
|
||||
|
||||
|
|