In the local reference mode, instead of returning the adjusted current
time as the reference time, return the same timestamp updated only once
per about 62.5 seconds.
This will enable chronyd to detect polling of itself even when the local
reference mode is active.
Add a new set of tests for testing basic functionality, starting chronyd
with root privileges on the actual system instead of the simulator.
Tests numbered in the 100-199 range are considered destructive and
intended to be used only on machines dedicated for development or
testing. They are started by the run script only with the -d option.
They may adjust/step the system clock and other clocks, block the RTC,
enable HW timestamping, create SHM segments, etc.
Other tests should not interfere with the system and should work even
when another NTP server/client is running.
Instead of linking unit tests with *.o in the root directory, which may
include conflicting objects from a different configuration (e.g. hash),
add a print target to the main Makefile and use it in the unit test
Makefile to link only with objects that are relevant in the current
configuration.
Fix mismatches between the format and sign of variables passed to
printf() or scanf(), which were found in a Frama-C analysis and gcc
using the -Wformat-signedness option.
Save the local receive and remote transmit timestamp needed for
(re)starting the symmetric protocol when no valid reply was received
separately from the timestamps that are used for synchronization of the
local clock.
This extends the interval in which the local NTP state is (partially)
protected against replay attacks in order to complete a measurement
in the interleaved symmetric mode from [last valid RX, next TX] to
[last TX, next TX], i.e. it should be the same as in the basic mode.
Similarly to the maxdelaydevratio test, include in the maximum delay
dispersion which accumulated in the interval since the last sample.
Also, enable the test for symmetric associations.
On some HW it seems it's possible to get an occasional bad reading of
the PHC (with normal delay), or in a worse case the clock can step due
to a HW/driver bug, which triggers reset of the HW clock instance. To
avoid having a bad estimate of the frequency when the next (good) sample
is accumulated, drop also the last sample which triggered the reset.
If the minimum delay is known (in a static network configuration), it
can replace the measured minimum from the register. This should improve
the stability of corrections for asymmetric jitter, sample weighting and
maxdelay* tests.
In interleaved client mode, when so many consecutive requests were lost
that the first valid (interleaved) response would be dropped for being
too old, switch to basic mode so the response can be accepted if it
doesn't fail in the other tests.
This reworks commit 16afa8eb50.
In symmetric mode, don't send a packet in interleaved mode unless it is
the first response to the last valid request received from the peer and
there was just one response to the previous valid request. This prevents
the peer from matching the transmit timestamp with an older response if
it can't detect missed responses.
If the -Q option is specified, disable by default pidfile, ntpport,
cmdport, Unix domain command socket, and clock control, in order to
allow starting chronyd without root privileges and/or when another
chronyd instance is already running.
Specify the maximum length of the path in the snprintf() format to avoid
a new gcc warning (-Wformat-truncation). If the path doesn't fit in the
buffer, indicate with the '>' symbol that it was truncated. The function
is used only for debug messages.