rtc: don't drop first sample after initial trim

It seems there is no longer an issue with the first sample after the
initial trim and it can be accumulated. It might have been a workaround
for an unrelated bug which was fixed since then.

This fixes the number of samples reported in rtcdata briefly jumping to
65535 and also brings back the expectation that n_samples is never
negative.
This commit is contained in:
Miroslav Lichvar 2021-11-29 12:30:09 +01:00
parent 22bfdf204f
commit 53353529cf

View file

@ -189,14 +189,10 @@ accumulate_sample(time_t rtc, struct timespec *sys)
}
/* Always use most recent sample as reference */
/* use sample only if n_sample is not negative*/
if(n_samples >=0)
{
rtc_ref = rtc;
rtc_sec[n_samples] = rtc;
system_times[n_samples] = *sys;
++n_samples_since_regression;
}
++n_samples;
}
@ -633,11 +629,7 @@ handle_initial_trim(void)
run_regression(1, &coefs_valid, &coef_ref_time, &coef_seconds_fast, &coef_gain_rate);
n_samples_since_regression = 0;
/* Set sample number to -1 so the next sample is not used, as it will not yet be corrected for System Trim*/
n_samples = -1;
n_samples = 0;
read_coefs_from_file();